On a bridge deck, a tunnel lining, a rail corridor or a tank farm, the coating is rarely the constraint. The constraint is that there is no socket within 300 metres. A gas (petrol) airless sprayer removes that constraint — but only when it is sized against the hose run and the tip, not against the pressure printed on the pump.

1. What self-powered actually buys you — and what it does not

A gas airless unit buys three things: no generator, no cable run across a live lane, and a start-up that does not depend on site electrics. The units we supply in the 7.5 HP and 13 HP classes reach up to 16 L/min and 3,300 psi (227 bar), with tip options from 0.015 to 0.021 in and a 50 ft hose. That is enough to hold a single gun at working pressure on materials from acrylics to high-solid epoxies — the same duty a fixed electric unit handles, without the lead.

It does not buy you more pressure at the tip than an electric unit of the same rating. Two consequences follow from the petrol engine, and both are routinely discovered on site rather than in the spec.

Exhaust is a confined-space hazard, not a nuisance. In tunnels, tanks and enclosed holds a petrol engine must run outside the work zone, with forced ventilation and CO monitoring. If the work is inside a tank, the correct answer is usually a pneumatic unit fed from a plant air line — not a petrol one with the door propped open.

Output falls as the engine heat-soaks and the air filter loads. The pump's pressure is set by a relief valve, but the engine driving it is not immune to a blocked filter or 40 °C ambient. Check the unit at the end of a shift, not the beginning; a machine that held 3,300 psi cold will not necessarily hold it after four hours.

2. Specify gun pressure; the gauge is at the pump

3,300 psi is deadhead pressure at the pump outlet. What the tip sees is that figure minus every loss in between: hose friction, swivels, the tip guard, the inlet filter. Losses rise with the square of flow and with viscosity, so a thin acrylic at 1.9 L/min through 50 ft of hose loses far less than a high-solid epoxy at the same flow through 150 ft.

The consequence is practical. A unit that sprays a primer perfectly through 50 ft can look "tired" on a 150 ft run — same pump, same tip, different result. Before blaming the machine, do one of three things: shorten the run, increase the hose ID, or move the pump closer and feed it. Do not solve a pressure-drop problem by opening the relief valve. You will only raise the flow, and with it the drop.

3. Match tip flow to pump flow, not tip size to habit

Flow through a tip scales with orifice area and with the square root of pressure. That single relationship explains most "the sprayer won't hold pressure" complaints, and it is why a 16 L/min headline figure tells you very little on its own.

Work from the tip chart. If a 0.017 in tip is rated 1.9 L/min at 3,300 psi, one gun draws 1.9 L/min and two guns draw 3.8 — under a quarter of a 16 L/min pump, so pressure holds through a second-gun trigger. Four guns at the same tip is 7.6 L/min: still nominally inside the pump rating, but now every swivel and every metre of hose is dropping pressure, and the gauge at the gun sags the moment the second gun fires.

Rule of thumb: keep total tip flow at or below roughly 70 % of the pump's rated maximum, and treat 0.021 in as the practical ceiling for a single gun on a 13 HP unit. If the job needs more coverage than that, add a second machine rather than a fifth gun — you are buying stability, not litres.

4. Fuel and duty cycle over an eight-hour shift

Two numbers decide whether a gas unit finishes a shift: fuel consumption at working load, and how often the gun is actually triggering. A unit held at relief pressure burns more and heats more than one cycling on a trigger, so a crew that sprays in long uninterrupted passes gets more out of the same tank than one stopping every few metres.

  • Ask for consumption at working pressure, not at idle, and size the tank against a full shift plus margin.
  • Plan one refuel and one filter check per shift on a 13 HP unit. On a 7.5 HP single-gun set-up a shift usually completes on one fill — confirm against the datasheet rather than assuming it.
  • Hold the injection distance inside the 400–550 mm band the machine was set up for. Changing distance mid-run moves film thickness more than any pressure adjustment will, and it is the change nobody records.